enLanguage
Seamless Titanium Tube For Heat Exchanger

Seamless Titanium Tube For Heat Exchanger

› Grade 2 seamless titanium tube
› ASTM B338 for condensers and heat exchangers
› OD 6-76 mm, wall thickness 0.5-3.0 mm
› Fixed lengths up to 6000 mm
› Prepared for tube expansion and tube-sheet assembly
› Pickled or bright annealed surface options
› ECT, hydrostatic testing and MTC documentation
› Send OD, wall thickness, length and quantity

Product Introduction

Product Introduction

  • Grade 2 seamless titanium tube is commonly used in shell-and-tube heat exchangers, condensers, evaporators, and seawater cooling equipment where corrosion resistance and stable heat-transfer performance are required.
  • Tube outside diameter, wall thickness, straightness, and internal surface condition are important for tube expansion, tube-sheet assembly, cleaning, and long-term fluid service.
  • ASTM B338 tubing can be supplied in fixed lengths with surface condition, tube-end preparation, testing, and documentation confirmed according to the equipment drawing and operating medium.

 

Seamless Titanium Tube for Heat Exchanger suppliers

 

Product Parameter

Item Specification
Material Grade Titanium Grade 2 / UNS R50400
Standard

ASTM B338

 

Tube Type Seamless, cold reduced or cold drawn
Outside Diameter Ø6 mm-Ø76 mm
Wall Thickness 0.5 mm-3.0 mm
Length Up to 6000 mm, fixed-length or cut-to-length supply
Supply Condition Annealed
Surface Finish Pickled / Bright Annealed / Polished
Mechanical Properties Tensile Strength ≥345 MPa, Yield Strength ≥275 MPa, Elongation ≥20%
Tube-End Preparation Square cut / Deburred / Prepared to drawing
Testing Eddy Current Testing, Hydrostatic Testing, UT, Dimensional Inspection, MTC
Applications Heat Exchangers, Condensers, Evaporators, Seawater Cooling Equipment

 

Product Features & Application

 
Heat Exchanger Applications
 
Seawater Cooling Systems
Seawater Cooling Systems
Heat Exchanger Tube Bundle
Heat Exchanger Tube Bundle
Chemical Process Heat Exchangers
Chemical Process Heat Exchangers

Tube-to-Tubesheet Fit

Outside diameter, wall thickness, straightness, and fixed length are controlled to support tube expansion and tube-sheet assembly.

Surface and Internal Cleanliness

Pickled or bright annealed surfaces can be supplied according to fluid cleanliness, heat-transfer, and equipment assembly requirements.

Inspection for Heat-Transfer Service
Eddy current testing, hydrostatic testing, ultrasonic testing, and dimensional inspection can be specified according to the order requirements.

By choosing the Seamless Titanium Tube for Heat Exchanger, operators can ensure longer intervals between maintenance and stable performance in demanding environments.

 

Quality Management

 

Inspection for Heat Exchanger Tubes

 

Chemical Composition Analysis (PMI)

Chemical Composition Analysis (PMI)

EddyCurrentTesting (ECT)

EddyCurrentTesting (ECT)

Flaring Test / Flattening Test

Flaring Test / Flattening Test

Positive Material Identification (PMI)

Positive Material Identification (PMI)

Eddy Current Testing (ECT)

Eddy Current Testing (ECT)

Mechanical Properties Test

Mechanical Properties Test

 

Package and delivery

 

  • Heat exchanger tubes are cleaned and separated by size, length, and material batch before packing. Tube ends can be protected to reduce contamination and impact damage during handling.
  • Long tubes are supported at suitable intervals inside the package to reduce bending, movement, and contact marks during transportation.
  • Wooden crates, internal spacers, protective wrapping, and end protection are selected according to tube dimensions, quantity, and shipping method.

 

Grade 2 Seamless Titanium TubeGrade 2 Seamless Titanium TubeGrade 2 Seamless Titanium Tube

 

FAQ

Q1: What grade of titanium tubing is typically used for heat exchangers?

A: In practical projects, Gr1 and Gr2 are the most common choices. The specific grade usually needs to be determined based on a comprehensive consideration of design pressure, tube sheet structure, and assembly method.

Gr1: Higher ductility, suitable for tube expansion or bending structures requiring high formability.
Gr2: Balances strength and formability, more commonly used in conventional industrial heat exchangers.

Q2: Are titanium tubes prone to cracking during expansion or welding processes?

A: Grade 2 titanium tube has practical formability and weldability. The risk of cracking or excessive springback can be reduced by confirming the annealed condition, wall thickness tolerance, expansion ratio, tooling, and welding procedure before fabrication.

Q3: Do titanium tubes require special surface treatment?

A: For most heat exchanger applications, pickled or bright annealed surfaces are sufficient. Internal cleanliness, surface condition, and compatibility with the working medium should be confirmed instead of applying unnecessary coatings.

Q4: Is it possible to customize non-standard size titanium tubes based on project requirements?

A: Yes. However, we need to confirm the design drawings, the medium of use, and the working temperature and pressure range to ensure that the dimensions and material specifications match the actual working conditions.

Q5: Can I order small trial batches?

A: Yes. Trial quantities can be reviewed according to the requested grade, dimensions, length, testing requirements, and current material availability.

 

testing certificate

 

product-3175-4490product-3175-4490product-3175-4490

 

 

 
we are here for you
write to us
Email: Jamesyang@zxb-titanium.com
Email: Johnlee@zxb-titanium.com
visiting us
Address: No. 107, Gaoya Industrial Park, High-Tech Zone, Baoji City, Shaanxi Province, China
whatsApp
Number: +86 177 2959 5257
Number: +86 177 2959 6223
 
Contact directly
Phone: +86 177 2959 5257
Phone: +86 177 2959 6223

 

 

 

Hot Tags: Seamless Titanium Tube For Heat Exchanger, China Seamless Titanium Tube For Heat Exchanger manufacturers, suppliers, factory

Send Inquiry

whatsapp

Phone

E-mail

Inquiry

Bag