Product Introduction
Titanium anodes used for sodium hypochlorite generation need to match the chloride-based electrolyte, cell layout and required chlorine-production duty. Ru-Ir MMO coated titanium is commonly selected for brine or seawater electrolysis systems because the coating system is suited to chloride media and can be configured for different cell structures.
For an actual order, the electrolyte type, chloride concentration, operating temperature, current density, cell dimensions, active area and connection structure should be confirmed together. The anode design should fit both the electrolysis conditions and the equipment layout.
Product Parameter
Typical values below are for general product definition only.
Final configuration should be confirmed according to electrolyte condition, output target and cell design.
|
Parameter |
General Reference |
Notes |
| Titanium Substrate | Grade 1 Titanium | Commonly used for coated anode fabrication |
| Coating System | Ruthenium-Iridium MMO | Selected for chloride-based electrolysis |
| Available Structure | Plate / Mesh / Finned Plate / Fabricated Assembly | Based on cell design and installation |
| Electrolyte | Brine or Seawater | Chloride concentration should be provided if available |
| Current Density | Confirmed according to output target and effective area | Final value depends on working conditions |
| Operating Temperature |
Reviewed according to actual system conditions |
Continuous operation condition should be clarified |
| Connection Type | Threaded Rod / Tab / Custom Connection | Matched to busbar and mounting layout |
| Typical Use | On-site NaClO Generation / Electrochlorination / Disinfection Systems | For new or replacement units |
| Inspection | Dimensional Check / Coated Area Confirmation / Connection Inspection | According to agreed purchase specification |
Product Features & Application



- On-Site Sodium Hypochlorite Generation
Titanium anodes are used in brine electrolysis systems where chlorine output, active area and cell arrangement need to be defined together. The anode structure should match the generator layout and required operating load.
- Seawater Electrochlorination
For seawater-based chlorination systems, the coating system and anode configuration should be reviewed according to chloride content, temperature and continuous operating conditions. This helps the anode fit the actual electrochlorination duty.
- Disinfection Units and Retrofit Projects
For modular equipment or replacement cells, plate or fabricated titanium anodes can be supplied according to existing dimensions, connection details and effective working area. Drawings or old-sample references are helpful for confirmation.
Product Details

- Structure Options
Depending on the generator design, the anode can be supplied as plate, mesh, finned plate or other fabricated forms. The final structure should match the cell arrangement, flow path and installation method.
- Coated Working Area
The active coated area should be defined according to the required output, current density and effective reaction zone. Coated and uncoated sections should remain clearly separated, especially at electrical contact positions.
- Connection and Installation
Threaded rods, tabs or custom connection parts can be arranged according to the busbar and mounting structure. For replacement orders, the existing fixing method should be confirmed before production.
- Application Review
Electrolyte type, salinity, temperature, operation mode and target output should be reviewed together before the final anode configuration is confirmed.
Project & Order Support

- System Review
We review the electrolyte condition, target output, current loading and anode configuration before the quotation is finalized.
- Drawing Matching
For custom or replacement cells, dimensions, active area, connection details and mounting structure can be checked from drawings, photos or sample references.
- Configuration Support
Plate, mesh or fabricated titanium-anode structures can be discussed according to the sodium hypochlorite generator design and installation requirements.
- Inspection Coordination
Dimensions, coated area, connection structure and other agreed verification items are coordinated according to the purchase specification.
FAQ
Q1: What information should be provided for a sodium hypochlorite anode quotation?
A: Please provide the electrolyte type, chloride concentration or salinity if available, operating temperature, current density or total current, cell dimensions, active area and quantity.
Q2: Is Ru-Ir MMO the standard coating choice for sodium hypochlorite generation?
A: In many chloride-based electrolysis systems, Ru-Ir MMO is commonly used. The final coating direction should still be confirmed according to the actual electrolyte and operating conditions.
Q3: Can you supply replacement anodes for an existing generator cell?
A: Yes. Replacement orders can be reviewed from drawings, old-sample dimensions, connection details and the original active working area.
Q4: How is the anode size determined?
A: It is determined by the required output, current density, effective area and cell arrangement. There is no single fixed size without process and equipment data.
Q5: Can inspection requirements be included with the order?
A: Yes. Dimensional checks, coated-area confirmation, connection inspection and other agreed verification items can be arranged according to the order requirement.

Company profile
Baoji Zhongxinbao Metal Materials Co., Ltd. supplies titanium materials and custom titanium anodes for electrochemical applications. For sodium hypochlorite generation systems, we can support plate, mesh and fabricated titanium anode configurations according to the electrolyte condition, cell layout and installation requirements.
For custom or replacement orders, we review active area, structure, connection details and inspection requirements before production. Product configuration and documentation are confirmed according to the agreed purchase specification.
we are here for you
Hot Tags: titanium anode for electrolysis sodium hypochlorite, China titanium anode for electrolysis sodium hypochlorite manufacturers, suppliers, factory, Desalination Plant Titanium Anode, Titanium Anode Tablets For Swimming Pool Disinfection, Titanium Mesh Anode For Water Treatment, Titanium Anode For Electrodialysis, Titanium Anode For Fruit And Vegetable Machine, Titanium Anode Mesh For Swimming Pool Disinfection